Tri Star CNC Services helps you diagnose and troubleshoot your FANUC spindle amplifier and other electronic components. If your CNC machine tool is throwing an error you need to track down the source of the problem—which isn’t always as easy as it sounds.
FANUC Parts We Service:
Free drivers for Philips SPC600NC/00. Found 5 files for Windows Vista, Windows XP, Windows 2000, Windows ME, Windows 98 SE. Select driver to download.
- 800 x 600 Interfaces. Computer Interface USB 2.0. Philips SPC Model 600NC PC Camera. Drivers & Utilities.
- Philips spc 600 nc00 driver. Free Download Files txt, which I believe is located in c qoobox The Royal Dutch Touring Club ANWB It s formatting right now. Philips spc 600 nc00 driver Download Philips spc 600 nc00 driver. Verdict Still the best option out there. SACD 122 3 S 2 Beethoven Piano Concerto 5 AX.
- FANUC Alpha, Alpha i series & Alpha is series
- FANUC AC Digital and Analog
- FANUC AC Serial Interface
- FANUC AC Series i & S
If you’ve tried everything, scoured every alarm code list you can find and still can’t get your part back in production, contact us today. You’ll get free over-the-phone support , and, if necessary, a quote for FANUC spindle repairs, a new FANUC spindle amp module or FANUC AC spindle amp.
Alarm Code | Description |
---|---|
Unit is not ready or not commanded to run. | |
Amplifier is ready (normal operating state) | |
SPM control program is not operating. | |
Error was detected in SPM control program processing. | |
Error was detected in the clock of the SPM control PCB. | |
Parity error was detected in the SRAM on the SPM control PCB | |
Spindle motor over temp | |
Actual motor speed is largely deviated from the commanded speed. | |
DC link fuse has blown | |
Detected that the 3-phase input to the main circuit of the PSM has an open phase. | |
AF2 or AF3 fuse blown. | |
Overspeed (Analog) | |
The motor rotates at a speed exceeding 115% (standard setting) of the maximum allowable speed. | |
+24V overvoltage. | |
Temperature of the heat sink of the SPM main circuit has risen to the set value. | |
Input power voltage dropped. | |
PSM detected that the DC link voltage was excessively high. | |
Excessively large current flowed into the DC link of the main circuit. | |
Memory inside the CPU is faulty. | |
ROM alarm | |
Spindle switching operation sequence was not executed correctly. | |
The memory (RAM) is faulty. | |
NVRAM is faulty. | |
ROM sum check alarm | |
The offset voltage of the phase U current detection circuit is excessively high. | |
The offset voltage of the phase V current detection circuit is excessively high. | |
VCMD offset alarm | |
TSA offset alarm | |
ER offset alarm | |
The power to the CNC is turned off. (This symptom does not represent an error.) Serial communication data transferred between the CNC and spindle amplifier module contains an error. | |
Serial communication between the CNC and spindle amplifier module stopped. | |
The sensor signal (for speed control) for Cs contour control has an error. | |
The sensor signal (position coder signal) for position control is abnormal. | |
The sensor signal (for position control) for Cs contour control is abnormal. | |
An excessive load (standard setting: load meter reading of 9 V) has been applied continuously for a certain period (standard setting: 30 seconds). | |
An excessively large current is detected at the input of the 3-phase main circuit of the PSM. | |
The motor failed to rotate as specified, and has stopped or is rotating at a very low speed. | |
LSI memory for serial communication is abnormal. A check is made when the power is turned on. | |
The PSM could not be charged within a specified time. PSM input has an open phase. | |
Parameter data outside the specifiable range was set. | |
The gear ratio set in a parameter exceeds the value range allowable for internal processing. This alarm is issued with a parameter related to orientation of magnetic sensor type. | |
Error counter overflowed. | |
After emergency stop signal input, the motor is accelerated without being decelerated. This alarm is issued also when the motor is not deactivated (the motor is not decelerated completely) when the acceleration/deceleration time (initial parameter setting: 10 seconds) has elapsed after emergency stop signal input. | |
The position where the one-rotation signal for Cs contour control is generated is incorrect. This alarm is not issued when the parameter indicated below is not set. | |
The one-rotation signal for Cs contour control is not generated. | |
The position where the one-rotation signal of the α position coder, BZ sensor, MZ sensor, α position coder S is incorrect. | |
The one-rotation signal of the α position coder, BZ sensor, MZ sensor, α position coder S is not generated. | |
The position coder signal of the spindle on the mater side used in the differential speed mode is disconnected. | |
An error occurred in the A/D converter. | |
The one-rotation signal of the position coder cannot be detected normally during thread cutting. | |
The count value of α position coder signal pulses is abnormal. The pulse count value of the MZ sensor or BZ sensor is abnormal. | |
Position coder 1 -rotation signal abnormality | |
In the differential speed mode, the spindle speed on the master side (remote) converted to a motor speed on the slave side (local) exceeded the maximum allowable speed of the motor. | |
A value obtained by internal calculation in spindle synchronization exceeded the allowable range. | |
The PSM detected that the DC link voltage was excessively low. | |
The synchronization signal (ITP) in communication data transferred to and from the CNC stopped. | |
The synchronization signal (ITP) in communication data transferred to and from the CNC stopped. | |
A large current flowing in the motor for a long time was detected. | |
In spindle switching control or output switching control, a mismatch between the switching request signal (SPSL or RSL) and the power line state check signal (MCFN, MFNHG, RCH, or RCHHG) continues during motor activation. | |
Internal cooling circuit faulty. | |
The temperature of the regenerative resistance of the PSM (resistance regenerative type) is excessively high. The PSM is faulty. | |
The temperature of the main circuit-cooling fan of the PSM is abnormally high. | |
The internal cooling fan of the PSM stopped. | |
Excessive semi-closed loop/closed loop position error alarm | |
Abnormal travel distance in magnetic pole determination operation | |
Error occurred during communication (connector JX4) between spindle and amplifier. | |
This alarm can be issued only when Dual Check Safety is in use. The alarm occurs if, in safety signal mode C (a guard open request was entered to open the guard), the spindle motor rotation speed exceeds entered to open the guard), the spindle motor rotation speed exceeds the safety speed. | |
This alarm can be issued only when Dual Check Safety is in use. The spindle amplifier connection status does not match the hardware setting. | |
This alarm can be issued only when Dual Check Safety is in use. A safety parameter error occurred. | |
This alarm can be issued only when Dual Check Safety is in use. The result of the spindle amplifier speed check does not match the result of the CNC speed check. | |
The signal of the motor sensor is disconnected. | |
This alarm can be issued only when Dual Check Safety is in use. The CPU test failed to end normally. | |
This alarm can be issued only when Dual Check Safety is in use. An error occurred in the CRC test. | |
This alarm can be issued only when Dual Check Safety is in use. The spindle safety function has not been executed. | |
This alarm can be issued only when Dual Check Safety is in use. The result of the spindle amplifier axis number check does not match the result of the CNC axis number check. | |
This alarm can be issued only when Dual Check Safety is in use. The result of spindle amplifier safety parameter check does not match the result of the CNC safety parameter check. | |
This alarm can be issued only when Dual Check Safety is in use. An abnormal operation was detected in the initial test. | |
An alarm was generated on the other spindle amplifier. | |
The position where the one-rotation signal of the motor sensor is generated is incorrect. | |
The one-rotation signal of the motor sensor is not generated. | |
The SPM checks the pulse counts of phases A and B each time a one rotation | |
The spindle sensor signal was disconnected. Refer to Alarm Code 73 for this alarm trouble shooting. | |
The one-rotation signal of the spindle sensor occurred in an incorrect location. Refer to Alarm Code 81 for this alarm trouble shooting. | |
No spindle sensor one-rotation signal occurred. Refer to Alarm Code 82 for this alarm trouble shooting. | |
A spindle sensor signal is abnormal. Refer to Alarm Code 83 for this alarm trouble shooting. | |
External cooling circuit faulty. | |
Sub module SM (SSM) error | |
Unexpected rotation alarm | |
Pole position count miss alarm | |
Velocity command-dependent overspeed alarm | |
The control program is not running. An error was detected when the control program was running. | |
An error occurred in communication between amplifier modules (SPM, SVM, and PSM). | |
Converter: control power supply low voltage | |
Converter: excessive regenerative power | |
Converter: cooling fan stopped of the radiator | |
An error occurred in serial communication data between the CNC and spindle amplifier module. | |
In spindle switching, a mismatch is found between the switching request signal (SPSL) and the internal status of the motor/spindle sensor signal switching circuit (submodule SW). | |
Speed polarity error in torque tandem operation | |
Serial data error | |
Data transfer error | |
Soft phase alarm | |
Device communication error | |
Pulse error alarm | |
Count error alarm | |
Serial sensor one-rotation signal not detected | |
If the SPM status display is 4, 11, 30, 33, 51, 57, 58, b1, b2, or b3 This status display means that an alarm condition occurred in the PSM. Check the status display of the PSM. |
Alarm Code | Message | Description |
---|---|---|
749 | S–SPINDLE LSI ERROR | It is serial communication error while system is executing after power supply on. Following reasons can be considered. 1) Optical cable connection is fault or cable is not connected or cable is cut. 2) MAIN CPU board or option 2 board is fault. 3) Spindle amp. printed board is fault. If this alarm occurs when CNC power supply is turned on or when this alarm can not be cleared even if CNC is reset, turn off the power supply also turn off the power supply in spindle side. |
750 | SPINDLE SERIAL LINK START FAULT | This alarm is generated when the spindle control unit is not ready for starting correctly when the power is turned on in the system with the serial spindle. The four reasons can be considered as follows: 1) An improperly connected optic cable, or the spindle control unit’s power is OFF. 2) When the NC power was turned on under alarm conditions other than SU–01 or AL–24 which are shown on the LED display of the spindle control unit. In this case, turn the spindle amplifier power off once and perform startup again. 3) Other reasons (improper combination of hardware) This alarm does not occur after the system including the spindle control unit is activated. 4) The second spindle (when SP2, bit 4 of parameter No. 3701, is 1) is in one of the above conditions 1) to 3). See diagnostic display No. 409 for details. |
751 | FIRST SPINDLE ALARM DETECTION (AL–XX) | This alarm indicates in the NC that an alarm is generated in the spindle unit of the system with the serial spindle. The alarm is displayed in form AL–XX (XX is a number). Refer to 2.3 or 2.4 Alarms displayed on spindle servo unit .The alarm number XX is the number indicated on the spindle amplifier. The CNC holds this number and displays on the screen. |
752 | FIRST SPINDLE MODE CHANGE FAULT | This alarm is generated if the system does not properly terminate a mode change. The modes include the Cs contouring, spindle positioning, rigid tapping, and spindle control modes. The alarm is activated if the spindle control unit does not respond correctly to the mode change command issued by the NC. |
754 | SPINDLE–1 ABNORMAL TORQUE ALM | Abnormal first spindle motor load has been detected. |
761 | SECOND SPINDLE ALARM DETECTION (AL–XX) | Refer to alarm No. 751. (For 2nd spindle) |
762 | SECOND SPINDLE MODE CHANGE FAULT | Refer to alarm No. 752.(For 2nd spindle) |
764 | SPINDLE–2 ABNORMAL TORQUE ALM | Same as alarm No. 754 (for the 2nd spindle) |
771 | SPINDLE–3 ALARM DETECT (AL–XX) | Same as alarm No. 751 (for the 3rd spindle) |
772 | SPINDLE–3 MODE CHANGE EROR | Same as alarm No. 752 (for the 3rd spindle) |
774 | SPINDLE–3 ABNORMAL TORQUE ALM | Same as alarm No. 754 (for the 3rd spindle) |
Spc 600 Nc Driver Windows 10
contact tri star cnc for repairs